Installation & Operation Manual
Mini Merlin
Pilot Water Heater and Boiler Limit Breaker
The device can be used to directly shut the pilot of a water heater using a product from Field
Controls. The BMS terminals may also be used to connect to a home alarm system.
Wiring example as shown.
Remote Shut-Off Connections
Your mini merlin can be integrated with remote devices with an open/close circuit via the
Remote Shut-Off volt free switch terminal.
This terminal has a factory fitted link installed.
This terminal is normally closed and will alarm when energised open - isolating the gas supply.
When using this input, only the mains utility output shall de-
energize. If you are using the CO or LPG relay to shut down a
boilers external limit circuit you will need to wire the remote
panic in series with the relay output.
Rev: 11 08-20