AGS Mini Merlin 설치 및 운영 매뉴얼 - 페이지 10
{카테고리_이름} AGS Mini Merlin에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AGS Mini Merlin 16 페이지. Ch4 co: dual gas detector methane & carbon monoxide
AGS Mini Merlin에 대해서도 마찬가지입니다: 사용자 설명서 (16 페이지), 설치 운영 및 유지보수 (20 페이지)
Installation & Operation Manual
Mini Merlin
Pilot Water Heater and Boiler Limit Breaker
The device can be used to directly shut the pilot of a water heater using a product from Field
Controls. The BMS terminals may also be used to connect to a home alarm system.
Wiring example as shown.
Remote Shut-Off Connections
Your mini merlin can be integrated with remote devices with an open/close circuit via the
Remote Shut-Off volt free switch terminal.
This terminal has a factory fitted link installed.
This terminal is normally closed and will alarm when energised open - isolating the gas supply.
When using this input, only the mains utility output shall de-
energize. If you are using the CO or LPG relay to shut down a
boilers external limit circuit you will need to wire the remote
panic in series with the relay output.
Rev: 11 08-20
10