2.3
Wiring (all models)
Wiring for all models is accomplished at rear of the gauge enclosure.
A separate kit included with gauge contains different size strain reliefs
to facilitate use with various gauge wire. Insert wire through correct
relief fitting and assemble strain relief as shown in Figure 6. Attach
strain relief assembly to gauge enclosure using four screws provided in
kit, as shown in Figure 7.
NOTE: This device operates on 12 VDC not 120 VAC
Fig. 6 & 7
2.4 Terminal Connections
5 Position Terminal Block -
Alarm Versions Only
1 Relay Contact (N.C.)
2 Common
3 Relay Contact (N.O.)
4 Reset
5 Automatic/Manual
(2 Position Terminal
Block - All Models)
1
12V Supply (-) (BLK)
2
12V Supply (+) (Red)
(Power Supply Terminal
Block -G115 Option)
1
Neutral (WHT)
2
115 or 230 (BLK)
DYNISCO PG500 Series
Fig. 8