Galvin Specialised Flowmatic TZ-FLOW225866 제품 설치 매뉴얼

BATTERY REPLACEMENT

Low battery indicator
When the battery requires replacement, the LED indicator light will blink at a constant rate when the user's hands
are within the sensor range. The battery must be replaced, as follows:
1. Disassemble:
Turn off the water supply.
To access the battery, unscrew the set screw located
at the underside part of the body using the 2mm
Allen key (supplied with the kit)
3. Replacing the battery:
Remove the old battery from battery cover and
disconnect it from the battery connector, .
Place the battery cover on the new 9V battery and
connect to battery connector.
IMPORTANT: Spent batteries should not be disposed of with normal household waste. Contact your local
authority for information on waste disposal and recycling.
Version 2, 16
2. Pull out sensor head:
Pull out the sensor cap carefully.
Verify that the O-ring on the sensor head and water
is in good condition. If needed, apply grease, or
replace it with 1.5mm x 38mm O-ring.
4. Assemble & Test:
Once the battery has been replaced, check there
are no objects in front of the sensor.
Wait 15 seconds to allow the system to set the ideal
sensor range.
th
March 2021, Page 6 of 9