LOCK AND UNLOCK EXTERIOR DOORS
1. Using a standard 216 style tool, or similar, turn the locking bolt located at the center of the IDC door
a ¼ turn clockwise to unlock and counter clockwise to lock the cabinet..
Note: A pad lock, not provided, may be utilized if additional security is desired.
DOOR REMOVAL AND RE-INSTALLATION
The IDC was designed so that the door may be installed on either side of the cabinet for applications where there are
space restrictions.
1. Lift up on the cabinet door to release it from the hinge pins.
3. Using local engineering practices determine which side of the cabinet the door is to be placed. Install the enclosure
door over the appropriate hinge pins.
3. Review the label and diagram orientation on the IDC door. If necessary, apply the included Replacement Door Label
Kit in the appropriate positioning.
4. Using a standard 216 style socket tool, or similar, lock the cabinet.
CABLE PREPARATION
Caution: Fiber optic cable is susceptible to damage
from excessive bending, pulling or crushing forces.
At every stage of the installation process ensure that
loose buffer tubes, ribbon or Wrapping Tube Cable
(WTC) with Spider Web
free from unintentional cuts, knick or bends to avoid
potential fiber damage.
1. Mark the cable to have a minimum 60" (152.4 cm) opening.
2. Use local accepted practice to remove the cable sheath.
3. Using wire cutters cut the central strength member back to the sheath opening.
Note: For best practice, when working with WTC it
is recommended accepted local practices be used
to protect the SWR fiber before continuing to the
cable installation.
Ribbon (SWR) fibers are
®
INSTALLATION INSTRUCTIONS
IDEAA
4
Interior Distribution Cabinet
®
60" (152.4 cm)
© 2016, AFL, all rights reserved. Revision C, 3.3.17
Specifications are subject to change without notice.