AGT INDUSTRIAL AGT-ST4040C 제품 설명서 - 페이지 5
{카테고리_이름} AGT INDUSTRIAL AGT-ST4040C에 대한 제품 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. AGT INDUSTRIAL AGT-ST4040C 10 페이지. 40ft x 40ft container roof shelter
Step 2 : Place the containers making sure they are parallel and the correct width
apart. Make sure there is a gap of about 3 feet around the building. the center
point of the round pipe of the base is the reference point, and the diagonal X and
Y must be equal. The bottom plate should be installed on the top of the container
on the same level to ensure a firm and reliable installation.
Parts used in this step. (refer to figure 1)
- (2) Baseplate for front and rear truss left corners (#6L)
- (2) Baseplate for front and rear truss right corners (#6R)
- (10) Baseplates for middle truss (#6)
- (14) Base clamp connector (#6A)
- (24) Base tube connecting plate (#6B)
- (48) Hex bolt (#14)
5
Figure 1