HIKOKI WR18DH 취급 지침 매뉴얼 - 페이지 11

{카테고리_이름} HIKOKI WR18DH에 대한 취급 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. HIKOKI WR18DH 20 페이지.

CHARGING
Before using the power tool, charge the battery as follows.
<UC18YSL3>
1. Connect the charger's power cord to the
receptacle.
When connecting the plug of the charger to a
receptacle, the charge indicator lamp will blink in red.
(See Table 1)
2. Insert the battery into the charger.
Firmly insert the battery into the charger as shown in
Fig. 4 (on page 2).
3. Charging
When inserting a battery in the charger, charging will
commence and the charge indicator lamp will blink in
blue.
When the battery becomes fully recharged, the charge
indicator lamp will light up in green. (See Table 1)
(1) Charge indicator lamp indication
The indications of the charge indicator lamp will be as
shown in Table 1, according to the condition of the
charger or the rechargeable battery.
Table 1: Indications of the charge indicator lamp
ON/OFF at 0.5 sec. intervals
(RED)
Lights for 0.5 sec. at intervals of
1 sec. (BLUE)
Lights for 1 sec. at intervals of
0.5 sec. (BLUE)
Lights continuously (BLUE)
Lights continuously (Continuous
buzzer sound: about 6 sec.)
(GREEN)
ON/OFF at 0.3 sec. intervals
(RED)
ON/OFF at 0.1 sec. intervals
(Intermittent buzzer sound:
about 2 sec.) (PURPLE)
NOTE
*1 If the red lamp continues to blink even after the charger
has been attached, check to confirm that the battery
has been fully inserted.
*2 Battery overheated. Unable to charge.
Although charging will start once the battery has cooled
down even when left in situ, the best practice is to
remove the battery and allow it to cool down in a
shaded, well-ventilated location before charging.
*3 Malfunction in the battery or the charger
Fully insert the battery.
Check to confirm that no foreign matter is stuck to
the battery mount or terminals. If there are no
foreign objects, it is probable that the battery or
charger is malfunctioning. Take it to your authorized
Service Center.
Before charging *
1
Charged at less than
50%
Charged at less than
80%
Charged at more
than 80%
Charging complete
Overheat standby *
2
Charging impossible
*
3
11
○ When the battery charger has been continuously used,
the battery charger will be heated, thus constituting the
cause of the failures. Once the charging has been
completed, give 5 minutes rest until the next charging.
(2) Regarding the temperatures and charging time of the
battery (See Table 2)
Model
Type of battery
Charging voltage
Temperatures at which the
battery can be recharged
1.5 Ah
2.0 Ah
2.5 Ah
Charging time for
3.0 Ah
battery capacity,
approx. (At 20°C)
4.0 Ah
5.0 Ah
6.0 Ah
1.5 Ah
(× 2 unit)
Charging time for
multi volt battery
2.5 Ah
capacity, approx.
(× 2 unit)
(At 20°C)
4.0 Ah
(× 2 unit)
Number of battery cells
Charging voltage for USB
Charging current for USB
Weight
NOTE
○ The recharging time may vary according to the ambient
temperature and power source voltage.
○ If charging takes a long time
Charging will take longer at extremely low ambient
temperatures. Charge the battery in a warm location
(such as indoors).
Do not block the air vent. Otherwise the interior will
overheat, reducing the charger's performance.
If the cooling fan is not operating, contact a HiKOKI
Authorized Service Center for repairs.
4. Disconnect the charger's power cord from the
receptacle.
5. Hold the charger firmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after
use, and then keep it.
<UC18YFSL>
1. Connect the charger's power cord to the
receptacle.
When connecting the plug of the charger to a
receptacle, the pilot lamp will blink in red. (See Table 3)
Table 2
UC18YSL3
Li-ion
14.4–18 V
0°C–50°C
15 min
20 min
25 min
20 min
(BSL1430C, BSL1830C:
30 min)
26 min
(BSL1840M: 40 min)
32 min
38 min
20 min
32 min
52 min
4–10
5 V
2 A
0.6 kg