Maintenance
Cartridge Cleaning
To clean the cartridge, follow
the steps below:
1. Isolate the hot and cold water
supplies. Remove the anti-tamper
cover (17).
Note: If you have purchased the
MT753CP-ISO, simply turn the screws
in the isolation assemblies (4G) to
isolate the water supplies.
2. Unscrew the head assembly (20)
from the body (12) using a suitable
spanner.
IMPORTANT: Note the position of
the Adjusting Screw (18) before
removing. It will need to be replaced
in the same position in order to
maintain the current maximum
temperature.
3. Remove the thermostat (10), piston
assembly (8), thermostat housing (16)
and return spring (11).
4. Soak all components in a suitable
solution until fully de-scaled. Check
all seals and O-Rings for damage and
replace if necessary.
5. Re-grease parts using a WRAS
Approved grease and reverse the
steps to re-assemble the valve.
6. Turn on the water supply and check
all joints and connections for any
leaks.
7. Follow the Temperature Adjustment
process to check and re-calibrate the
maximum temperature.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
MT753CP-ISO Isolation Valve
Assembly Parts
Part
Description
No.
4A
22mm Body
4B
Plated Brass Ball
4C
PTFE Seat
4D
22mm Copper Olive
4E
22mm Compression Nut
4F
Brass Nut
4G
Actuating Stem
4H
O-Ring
4I
Connecting Nut
4D
4E
4F
4G
4H
4I
Qty
1
1
2
1
1
1
1
1
1
4C
4B
4A
7