IMPORTANT:
• Must be installed in accordance with AS/NZS 3000.
• Must be installed to the manufacturers' specifications.
• Power supply must be installed by a licensed electrician.
• If the power cables are damaged, for any reason, do not use. Have the cord replaced
immediately.
• A means for switching off and isolating the appliance, for maintenance requirements, is
recommended.
• In all heat zones the wiring should be thermally insulated with the silicone sleeves
provided.
The cable for the control switch and thermostat switch is made with a high
temperature rated silicon outer case.
your electrician, standard electrical cables can be used outside of the heat zones. The
240 Volt supply cord and plug is not supplied; confirm length of supply cord required with
electrician.
Mount the control switch into wall, do not mount in wall above the heater or within
200mm from each side of the heater.
See installation instructions on page 5.
If additional cabling is required check with
2