Green Brook KingShield Orion Range 빠른 시작 매뉴얼

{카테고리_이름} Green Brook KingShield Orion Range에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Green Brook KingShield Orion Range 2 페이지. Infra-red motion sensor - wall switch

Please read these instructions carefully before installation and keep safe for future reference.
IMPORTANT
This product should be installed by a competent person and in accordance with the current
IET Wiring Regulations and Building Regulations.
If in doubt,consult a qualified electrician.
Always turn off the mains supply before commencing work.
As the detector responds to changes in temperature, avoid the following situations:-
Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors
etc.
Avoid mounting the detector near heat sources, such as heating vents, air conditioning
units, lights etc.
Avoid pointing the detector towards objects that may move in the wind, such as curtains,
tall plants etc.
Switch the mains supply OFF first to prevent electric shock.
1. Unclip both face plates using a small
flat-blade screwdriver, refer to Dia:1.
Dia:1
'Orion Range'
Infra-red Motion Sensor - Wall Switch
Model: OD100
Important Safety Instructions
FIELD OF DETECTION
INSTALLATION
Model: OD100 -
Function Switch:
'ON'
= Permanently ON
'OFF'
= Permanently OFF
'PIR"
= PIR Control
2. Connect the Live in wire to the 'L'
terminal and Load out wire to the 'A'
terminal, refer to Dia:2.
Dia:2
L
A