Deckma OMD Series 서비스 및 청소 매뉴얼 - 페이지 4
{카테고리_이름} Deckma OMD Series에 대한 서비스 및 청소 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Deckma OMD Series 13 페이지. Cleaning procedure of measuring cell mz-09
DECKMA
HAMBURG
1.
Measuring Cell Cleaning
1.1 Cleaning Manually
Step 1.
Stop any water flow.
Step 2.
Figure 1
Unscrew Cell Cap, MCU, or Autoclean.
Step 3.
Figure 3
Figure 2
Remove Cell Cap, MCU, or Autoclean.
1. For cleaning the Sample Glass Tube, use
the Cell Cleaning Brush with upwards
and downwards motion through the
Measuring Cell several times. Use some
water to wet the Cell Cleaning Brush.
2. Remove the Cell Cleaning Brush and
replace the Cell Cap.
3. Switch clean water valve to fresh water
and allow oil free water to flow through
the instrument for few minutes.
4. Avoid air bubbles in the stream.
5. Verify, that the display shows 0 to 2 ppm.
6. Cleaning has been sufficient if display
shows 0 to 2 ppm.