Major tech MT1883 사용 설명서 - 페이지 11
{카테고리_이름} Major tech MT1883에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Major tech MT1883 16 페이지.
6.
Apply power to the circuit.
7.
Read the current on the display. The display will indicate the
proper decimal point value.
4.6. Resistance Measurements
Warning: To avoid electric shock, disconnect power to the unit under
test and discharge all capacitors before taking any
resistance measurements. Remove the batteries and
unplug the line cords.
1.
Set the function to the Ω position.
2.
Insert the black test lead banana plug into the negative (COM)
jack and the red test lead banana plug into the positive Ω jack.
3.
Touch the test probe tips across the circuit or part under test. It
is best to disconnect one side of the part under test so the rest of
the circuit will not interfere with the resistance reading.
4.
Read the resistance on the display. The display will indicate the
proper decimal point value.
4.7. Continuity Check
Warning: To avoid electric shock, never measure continuity on
circuits or wires that have voltage on them.
1.
Set the function switch to the
2.
Insert the black lead banana plug into the negative jack (COM)
and the red test lead banana plug into the positive jack (Ω).
3.
Touch the test probe tips to the circuit or wire you wish to check.
4.
If the resistance is less than approximately 50Ω, the audible
signal will sound. The display will also show the actual resistance.
4.8. Diode Test
Warning: To avoid electric shock, do not test any diode that has
voltage on it.
1.
Set the function switch to the
2.
Insert the black lead banana plug into the negative jack (COM)
and the red test lead banana plug into the positive jack (Ω).
3.
Touch the test probe tips to the diode or semiconductor junction
you wish to check. Note the meter reading.
position.
position.
11