Gantner GAT Access 6100 F 사용자 설명서 - 페이지 3

{카테고리_이름} Gantner GAT Access 6100 F에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Gantner GAT Access 6100 F 4 페이지. Access control terminal with biometry

Mounting and installation instructions
1. Mounting holes
Drill mounting holes on a flat background (e.g. concrete wall) according to
the following dimensional drawing. Use the three holes labelled (a).
94.4 mm (3.72")
69 mm (2.72")
60 mm (2.36")
13 mm
(0.51")
a
a
a
Flush cabling
20 mm
(0.79")
2. Connection cable
The connection cables (power supply, network etc.) are run through the
cable lead-ins of the GAT FR 055. With concealed/flush wiring (1) the
connection cables are fed from behind via the back box. With surface
wiring (2) the connection cables must lie in the cable duct on the back
part of the GAT FR 055.
1
2
3. Wall mounting
Pay attention when fixing to an uneven background that the GAT FR 055
housing and the device back part of the GAT Access 6100 F must not
be distorted. Recommended mounting height: top edge of device 1.3 m.
2
1
4
5
7
6
www.gantner.com
3
1. GAT FR 055
2. Device back part of
GAT Access 6100 F
3
3. Fastening screws
4. Connection cable
5. Connection cable GAT FR 055
to GAT Access 6100 F
6. Weather protection cover
(optional)
7. Fastening screws for weather
protection cover
4. Electrical connection
The connection cables (see (4) in previous drawing) are connected at the
device back part of the GAT Access 6100 F (se page 4).
5. Mounting of the GAT Access 6100 F upper part
The connection cable of the GAT FR 055 (1) is fixed into the housing
upper part of the GAT Acces 6100 F and the connection cable of the
upper part (2) is fixed in the back part of the GAT Access 6100 F. After
that the device upper part can be swung down into the back part (3).
1
2
Check the sockets (1) and (2)! Dirt, dust and humidity must be removed so
that a good contact of the connection cable is guaranteed. No aggressive
detergent may be used. Please do not damage socket contacts.
Attention: Cleaning only in powerless state!
6. Open the GAT Access 6100 F upper part
The GAT Access 6100 F an only be opened with the supplied special tool!
With this the two catches on the bottom of the device can be unlocked in
succession.
Maintenance
The sonsor field of the GAT FR 055 should be cleaned from time to time
so that finger prints can be clearly scanned.
For cleaning the sensor field always use a humid (not wet!) smooth
cloth. No sharp or acrid detergents and no sharp materials must be
used!
Valid as from July 31
2013 • Technical data subject to modifications without notice!
th
DB_GAT-ACCESS6100F--BIO-EN_11.indd • PartNo.: 243526
1
2
3
3