Make Electrical Connection

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover using a T10 Torx
T10 adapter provided) to remove screws.
3. Remove the knockout in the terminal box and install a UL
listed or CSA approved
A. Knockout
B. Terminal box
C. Terminal box cover
4. Run home power supply cable through strain relief, into
terminal box.
A
C
D
E
A. Home power supply cable
B. UL listed or CSA approved strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-green ground wires
10
®
drive (or the
" strain relief.
A
B
C
B
F
5. Use UL listed wire connectors and connect black wires (C)
together.
6. Use UL listed wire connectors and connect white wires (E)
together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.

Install Vent Covers

When using both upper and lower vent covers, push lower cover
down onto hood and lift upper cover to ceiling. Install with 2 - 4.2
x 8 mm T20
®
screws using a T20
provided) to tighten.
NOTE: For vented installations, the upper vent cover may be
reversed to hide slots.
B
A
A. Bracket
B. 4.2 x 8 mm T20
C. Vent cover
®
Torx
®
drive (or T20
®
adapter
C
®
screws