Non-Vented (recirculating) Installation Through the
Soffit/Cabinet
Measure and mark the centerline location for the cutout in the
cabinet top. Use a saber saw or keyhole saw to cut an
opening for the vent.
A
A. Cutout
B. Vent cover (installation without soffit)
C. See the following chart.
³⁄₄
D. 7
" (19.7 cm) centerline to cabinet front
E. Centerline
Cabinet Height
Hole Shape and Size
12" (30.5 cm)
A 6¼" deep x 8" wide (15.9 cm x 20.3 cm)
rectangular opening in the cabinet top is
required for damper transition clearance.
15" (38.1 cm)
A 6¼" (15.9 cm) diameter round opening is
cabinet or soffit
required.
installation
18" (45.7 cm) or
A 5¾" (14.6 cm) diameter round opening is
24" (61.0 cm)
required.
B
D
C
E
Measure and mark the centerline of the cabinet to the soffit
above.
Measure from the bottom of the cabinet to the centerline of
the where the vent will come through the soffit. Mark the
location and use a saber saw or keyhole saw to cut a 5¾"
(14.6 cm) hole for the vent cover. Attach the vent cover using
two 4.5 x 13 mm #2 Phillips screws.
A. Vent cover
B. Centerline
For non-vented (recirculating) installations only, the range
hood can be vented indoors through the top of the cabinet.
For non-vented (recirculating) installations, charcoal filters are
necessary. See the "Range Hood Care" section for
instructions on installing charcoal filters.
The Charcoal Filter Kit Part Number W10272068 must be
used.
Complete Preparation
2. If it is not yet attached, install the 6" (15.2 cm) vent transition
to the top of the range hood liner using two 3.5 x 9.5 mm T10
screws.
A. Vent transition
B. 3.5 x 9.5 mm T10 screws
3. Install the vent system according to the method needed. Use
caulking to seal the exterior wall or roof opening.
A
B
A
B