GAPOSA XQ Sileo XS 60 매뉴얼 - 페이지 7
{카테고리_이름} GAPOSA XQ Sileo XS 60에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. GAPOSA XQ Sileo XS 60 16 페이지. Tubular motors with encoder electronic limits
GAPOSA XQ Sileo XS 60에 대해서도 마찬가지입니다: 매뉴얼 (15 페이지)
ELECTRICAL CONNECTION
IMPORTANT INFORMATION FOR ELECTRICIANS
• It is possible to connect in parallel electronic motors to a switch in
residential applications where the total power cable length does
not exceed 10 meters. The number of motors paralleled together
is limited to 4-5 according to the switch total amperage capacity.
• Electronic motors cannot be paralleled connected together
when controlled by a Building Management system (BMS).
• Compatibility between electronic motors and BMS must be
approved and tested by manufacturer of BMS.
• For standard motor operation only a standard switch allowing either
UP or DOWN but not both at the same time must be used. Only
mechanically or electrically interlocked switches can be used.
• Motors with electronic limits can be connected in parallel. The
maximum load of the switch must never be exceeded.
• When changing from UP to DOWN or vice versa, the switchover time
must at least be 0.5 seconds and effected through an OFF position.
Only switches with a defined neutral position or one with a built-in
switching delay should be used.
• An "active path" control unit which monitors the current draw is in
conflict with the motor and cannot be used.
2/2