CORNING SCF-1728 매뉴얼 - 페이지 9

{카테고리_이름} CORNING SCF-1728에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. CORNING SCF-1728 14 페이지. Heat shrink open ribbon system (hs-ors) canister splice closure

CORNING SCF-1728 매뉴얼
Step 8: Open the plastic clip on the splice plane ("C") and lay
the fibers inside.
Step 9: Carefully close the clip (Figure 18).
Step 10: Lay the fibers all the way down the splice plane on
the side of the organizer while maintaining a full loop
of slack in the storage area.
Step 11: Temporarily secure the fibers at the bottom of the
ORS with another piece of tape (Figure 19).
Step 12: Repeat
Section 10
TPA-6010
11.

Splice

Step 1:
Prepare fibers and splice:
a. To ensure the appropriate length of slack
fibers, cut the fibers extending beyond
the bottom of the closure as shown in
Figure 20.
b. Remove the tape from the fibers.
c. Remove the fibers from the top plastic clips.
d. Lay all fibers on the table.
e. Determine which two ribbon fibers are to
be spliced (one from the left and one from the right).
f.
Route them through the clip again and into the bottom of the closure. Do not close the clip at this
time.
g. Bring the two fibers to the appropriate position in the organizer.
h. Temporarily lay the fibers in the organizer to determine the required length.
i.
Cut both fibers at the same time in the center of the organizer.
for the other side.
TPA-6009
TPA-6011
Standard Recommended Procedure 206-455-AEN | Issue 1 | November 2018 | Page 9 of 14
Figure 18
Figure 19
Figure 20