CORNING MRU 어셈블리 설치 매뉴얼 - 페이지 6
{카테고리_이름} CORNING MRU에 대한 어셈블리 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. CORNING MRU 12 페이지. Mid-power remote unit outdoor enclosure mimo
7.
CONNECT RF ANTENNA COAX
For both 4.3-10 Type "ANTENNA PORT" and "2.5 GHz INPUT
PORT" - route coax cables (with 90-degree right-angle
connector) through their designated knockouts (see Figure
2) behind and above both MRU chassis and connect to the
corresponding RF ports. Refer to Figure 9.
8.
ROUTE FIBER AND POWER CABLES
IMPORTANT! If cables are routed without the use of conduits,
the knockouts must be sealed using appropriate sealing
materials.
Route optic fiber from fiber switch and power cables, for
both MRUs, through designated knockouts (see Figure 2) and
connect according to instructions in MRU quick installation
sheet. Refer to Figure 9.
Note: For DC power connections – route DC power cable with
open wires (without connector) and then wire according to
instructions in MRU quick installation sheet (CMA-398-AEN).
Corning Optical Communications
Figure 9. Example of Routed
Connection Cables
Quick Installation Sheet | CMA-595-AEN | Page 6