KitchenAid 9752397 설치 지침 매뉴얼 - 페이지 3
{카테고리_이름} KitchenAid 9752397에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. KitchenAid 9752397 7 페이지. 30" (76.2 cm) sealed burner gas freestanding and slide-in ranges, with self-cleaning thermal/convection oven
Slide-in ranges:
Tools needed for
countertop
preparation
installation:
30-319"
(77.2 cm) -
openmg\
___!_1AL
countertop
opening.
The cooktop sides of the slide-in range fit over
the cutout edge of your countertop.
If you have a square finish
(flat) countertop
and the opening
width
is 30-3/8" (77.2 cm),
no countertop
preparation
is required.
Formed front-edged
countertops:
Must have
molded edge shaved flat l/4" (0.64 cm) from
each front corner of opening.
Tile countertops
may need trim cut back
l/4" (0.64 cm) from each front corner and/or
rounded edge flattened.
Cooktop
sides df raAge fit over
edges of countertop
opening.
If countertop
opening
width is greater than
30-3/8" (77.2 cm), adjust the l/4" (0.64 cm)
dimension.
Countertop
must be level. Place level on
countertop, first side to side; then front to back.
If countertop
is not level, range will not be level.
Oven must be level for satisfactory baking
conditions.
measurina
taoe
rhammer
%?
le
Ge&
' 111
-/I/
i'
sarery
glasses
4
v
112" (1.3 cm)
Product dimensions
Freestanding
Range
8-W
(21 Cl
It
1 -l/2"
(3.8, cm)
diameter
.
W
router bit
hand or electric
drill
wood floor:
l/8" (0.3 cm) drill bit
concrete/ceramic
floor:
3/16" (0.48 cm)
carbide-tipped
masonry
drill bit
L.P. gas conversion
requires:
pin pick up (claw
attachment)
5116" nut driver
Parts supplied for
installation:
l
burner
grates
and caps
l
vent cap
l
L.P. conversion
orifice
spuds
kit:
2 x #64 cook-top
2 x #69 cooktop
1 x #65 broil burner
(Bracket
must be securely
mdunted
to sub-floor.
Thickness
of flooring
may require
longer screws
to anchor
the bracket
to sub-floor.)
Mobile home installation
The installation of this range must conform to the
Manufactured Home Construction and Safety
Standards, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD, Part 280); or when such
standard is not applicable, the Standard for
Manufactured Homes Installations (Manufactured
Home Sites, Communities and Setups), ANSI
A225.1/NFPA 501A*, or with local codes.
In Canada, the installation of this range must conform
with the current standards CANESA-Z240
-
latest
edition*', or with local codes.
When this range is installed in a mobile home, it must
be secured to the floor during transit. Any method of
securing the range is adequate as long as it conforms
to the standards listed above.
Copies of the standards
listed may be obtained
from:
l
National
Fire Protection
Association
Batterymarch
Park
Quincy, Massachusetts
02269
l
* Canadian
Standard
Association
178 Rexdale Boulevard
Etobicoke
(Toronto),
Ontario
M9W lR3
IMPORTANT:
Rear vent must be
installed on all
slide-in models for
proper ventilation.
See Step 7.
Panel
B
Anti-tip bracket:
The floor anti-tip
bracket
MUST be installed.To
install
the anti-tip
bracket shipped
with the range, see Panel D
and the anti-tip
bracket
template.
with