Gardena 1481 사용 설명서 - 페이지 11

{카테고리_이름} Gardena 1481에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Gardena 1481 18 페이지. Pressure tank unit electronic plus with dry-running safety
Gardena 1481에 대해서도 마찬가지입니다: 사용 설명서 (19 페이지)

Gardena 1481 사용 설명서
Cleaning the Integrated Filter
Cleaning the Integrated Back-Flow Valve
Always remove the mains plugs before working on the
pump.
Set or leave the switch on RUN.
.
If necessary, close the shut-off device on the inlet side of the
.
pump.
Unscrew the filter lid by turning anti-clockwise.
.
Remove the filter unit by pulling vertically upwards.
.
Hold the container and remove
.
the filter from the bayonet
socket by turning anti-clock-
wise.
Rinse the container under run-
.
ning water and clean the filter
using a soft brush, for example.
Reassemble the container-
.
filter unit in reverse order.
Insert the cleaned filter unit
.
into the pump.
Screw on the filter lid until tight.
.
Always remove the mains plugs
before working on the pump.
Set or leave the switch on RUN.
.
Ensure that the delivery side is de-
.
A
pressurised, for example, by opening
the consumers.
Close any shut-off devices on the inlet and
.
delivery side.
Loosen the screw by turning it anti-clockwise
.
until you can push the holder upwards and
backwards into opening position.
Remove the lid of the integrated back-flow valve by turning
.
anti-clockwise.
Remove the valve body and rinse under clean running water.
.
After cleaning, replace the valve body centrally in the correct
.
position (cone point downwards).
Screw on the lid until tight.
.
Push the holder forwards and position it in its original position.
.
Then tighten the screw again by turning it clockwise.
23