Gardena WP 600 작동 지침 - 페이지 5

{카테고리_이름} Gardena WP 600에 대한 작동 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Gardena WP 600 8 페이지. Fountain pump 12 v
Gardena WP 600에 대해서도 마찬가지입니다: 사용 설명서 (8 페이지), 사용자 설명서 (6 페이지), 사용 설명서 (7 페이지)

Gardena WP 600 작동 지침
G

Operation

Installing the pump
1. Remove the pump from the filter basket and screw the regulator
supplied onto the second opening of the pump up to the limit
stop (➔ max. delivery capacity on the vertical outlet). Then
replace the pump in the filter basket.
2. Put the pump on a stable base to ensure that the upper edge of
the filter tank is completely immersed in water.
Pay attention to
Please note the maximum submersion depth (see "Technical Data").
minimum water depth
Finding a location
GARDENA lightline Transformers are licensed for outdoor use.
for the transformer
You may attach them to the ground or the wall.
.
When attaching to the wall, please take care that the connection
.
sockets are pointing towards the ground.
When attaching to the ground, please take care that the trans-
.
former is not exposed to direct rainfall or to a mechanical
hazard.
2 m
2 m
Starting the pump
Put the plug connection into a free socket of the transformer
and connect the power cable of the transformer with a 230 V AC
socket.
Caution! Pump will start running immediately!
A
Avoid dry operation
Avoid dry operation of the pump as dry running will produce
undesirable heat and destroy the pump.
Horizontal or
Loosen the regulator by turning it anti-clockwise until you
.
second outlet
achieve the desired water flow from the vertical pipe of the
fountain / water feature.
You may connect other terminals to the second outlet.
.
For example, a separately installed water jet may be operated
via the GARDENA light jet base, Art. No. 7886. If necessary
fix the light jet base with two screws.
Information:
This significantly reduces the volume of the vertical water jet.
If the max. delivery capacity of the second outlet is to be used
.
then the vertical outlet should be closed with the end cap sup-
plied.
14
Example:
.
Hose pipe connection with the GARDENA light jet base
We recommend the use of a 3 /4" (19 mm) GARDENA pond
hose pipe, Art. No. 7895, connected to with the GARDENA
"Profi" Maxi-Flow-System with Tap Connector (Art. No. 2801
and 2802) and the GARDENA "Profi" Maxi-Flow-System Hose
connectors (Art. No. 2817).

Care instructions

Cleaning the filter tank
Filter tank and pump should be free from dirt particles!
How to clean :
Pull the plug connections out of the transformer and disconnect
.
its power plug!
Remove the pump from the water.
.
If necessary remove the gravel.
.
Clean the pump and the filter using a water jet.
.
If there are deposits of dirt inside the pump then dismantle the
.
casing (➔ ➔ see „Dismantling") and carefully clean the interior
fittings with water.
Information: Do not use any hard objects or strong detergents!
Blocked feed impeller
If the feed impeller becomes blocked, the pump and the filter
should be cleaned (see above).
Dismantling
1. Pull the plug connections out of the transformer and disconnect
its power plug!
2. Remove the pump from the water.
3. If necessary remove the gravel.
4. Pull the pump pointing vertically upwards out of the filter tank.
6
5
4
3
1
Then assemble all the fittings reversing the order and direction
.
in which they were dismantled. Please take care that the seal
5
ring
➔ Make sure while assembling that you attach the pump casing
with the pressure joint being cated, press it firmly and then
turn it straight to the right.
➔ Observe the markings.
5. Pull the suction filter casing
wards and remove it.
2
6. Remove the foam filter
from the
suction piece of the pump.
3
7. Turn the pump casing
to the left
2
to the limit stop and then pull it straight
towards the front and remove it!
Do not tilt!
8. Pull the feed impeller
4
out of the
6
motor casing
.
is properly re-fitted.
G
1
for-
15