5. Find the connector for the room thermostat with the number TA1 (if you have a boiler by Ariston),
or TA,LS-LR,COM-NO (if you have a boiler by any other manufacturer but Ariston). Disconnect the connector
on TA1, and connect the 2-strand wire, as shown on the picture.
6. Connect one end of the power cable
to the process control block (PCB),
and another end of the power cable
to the printed circuit board, as shown
on the picture.
Make sure that everything is connected
according to the instructions, and switch
on the central heating boiler. If the power
cable is connected to the process control
block (PCB), the red light appears
while the green light of
Status
06
is blinking.
2-strand Wire
TA1
5
6
Red Light of
Power Indicator
Green Lights
of Status
Power Cable
Printed Circuit Board