AlkaViva Athena H2 수동 부록

{카테고리_이름} AlkaViva Athena H2에 대한 수동 부록을 온라인으로 검색하거나 PDF를 다운로드하세요. AlkaViva Athena H2 2 페이지. Replacing the filter(s) in your h2 series ionizer
AlkaViva Athena H2에 대해서도 마찬가지입니다: 빠른 시작 Quide (2 페이지)

AlkaViva Athena H2 수동 부록
Vesta H2, Athena H2, Melody II
Recommended Method for Manually Adjusting
While AutoAdjust automatically provides very fine real-time adjustments to the pulse width, you can also manually
adjust the power to best suit your unique water quality and desired performance requirements. By manually changing
the power-steps for each Alkaline and Acidic level, you can change the main power settings, making bigger and more
impactful changes in performance. There are 4 Power Levels (1 – 4). Power Level 1 is the lowest and Power Level
4 the highest. Follow this procedure to adjust the Power Levels:
1.
Start with unit plugged in, water flow turned off.
2. Simultaneously press and hold the Alkaline 1 and Alkaline 2 buttons for 3—5 seconds, until the screen
looks like Fig. 1.
3.
Press and release the Alkaline 2 button 6 times. The display should now look like Fig. 2
4. Each time the Acidic 1 button is pressed, the display will cycle through the alkaline and acidic levels,
first in Forward polarity and then in Reverse polarity. (refer to Fig. 3a, 3b, and chart 3c)
Manual Addendum
Power Settings
Fig. 1
Fig. 2
4/4/2017
© AlkaViva, LLC
.