Function Display

NOTE: GTX 330 options are normally set at time of installation. For changes
to the GTX 330 parameters, contact your Garmin authorized dealer.
CRSR Initiates starting time entry for the Count Down timer and
cancels transponder code entry.
CLR Resets the Count Up, Count Down, and Flight timers. Cancels
the previous keypress during code selection and Count Down entry.
Returns cursor to the fourth code digit within five seconds after entry.
8 Reduces Contrast and Display Brightness when the respective fields
are displayed (dependent upon installation configuration) and enters
the number eight into the Count Down timer.
9 Increases Contrast and Display Brightness when the respective
fields are displayed (dependent upon installation configuration) and
enters the number nine into the Count Down timer.
FLIGHT ID: Displays the Flight ID. The CRSR key opens the Flight
ID entry dialog if the 'ALLOW PILOT TO EDIT FLT ID' option is en-
abled during installation configuration.
PRESSURE ALT: Displays the altitude data supplied to the GTX 330
in feet, hundreds of feet (i.e., flight level), or meters (dependent upon
installation configuration).
FLIGHT TIME: Timer start is configured as either Manual or Au-
tomatic. When Manual, displays the Flight Time, controlled by the
START/STOP and CLR keys. When Automatic, the timer begins when
takeoff is sensed.
ALTITUDE MONITOR: Controlled by START/STOP key. Activates
a voice alarm and warning annunciator when altitude limit is exceed-
ed.
OAT/DALT: Displayed when the GTX 330 is configured with tem-
perature input. Displays Outside Air Temperature and Density Alti-
tude.
COUNT UP TIMER: Controlled by START/STOP and CLR keys.
COUNT DOWN TIMER: Controlled by START/STOP, CLR, and
CRSR keys. The initial Count Down time is entered with the 0 – 9
keys.