Pump Installation
Mounting the Pump
Before you can mount the pump, you must select a location
determine the correct mounting hardware
1 Hold the pump in the intended mounting location and mark the locations of the mounting holes on the
mounting surface, using the pump as a template.
2 Using a drill bit appropriate for the mounting surface and selected mounting hardware, drill the four holes
through the mounting surface.
3 Secure the pump to the mounting surface using the selected mounting hardware.
Connecting the Hydraulic Hoses to the Pump
For assistance, see the layout diagrams
1 Disconnect the necessary hoses from the hydraulic system.
2 Add a T-connector to the starboard and port hoses of the hydraulic system between the helm and the
steering cylinder.
NOTE: If the boat has a power-assist module, you must add the T-connectors between the power-assist
module and the steering cylinder.
3 Complete an action:
• If the boat does not have a return hose connected to the helm, add enough hydraulic hose to connect the
return fitting on the helm to the pump.
• If the boat has a return hose connected to the helm, add a T-connector to the return hose.
NOTE: If the boat has a power-assist module, you must add the T-connector to the return hose between
the power-assist module and the helm.
4 Add hydraulic hose to the unused fitting on each T-connector, with enough hose to connect the T-connector
to the pump fittings.
5 Install a shut-off valve (not included) on each hydraulic hose from the T-connector to the pump.
6 If you added hydraulic hose to the return fitting on the helm, install a shut-off valve (not included) on the
hydraulic hose from the helm to the pump.
7 Connect the port and starboard hoses from the T-connectors, through shut-off valves, to the appropriate
pump fittings, as shown in the layout diagram for your hydraulic configuration.
8 Complete an action:
• If you added hydraulic hose to the return fitting on the helm, connect the return hose from the helm,
through a shut-off valve, to the center pump fitting.
• If you added a T-connector to an existing return hose, connect the return hose from the T-connector,
through a shut-off valve, to the center pump fitting.
9 Install the Shadow Drive valve in the port or starboard hydraulic hose between the helm and the T-connector
that connects to the pump
Connecting the CCU
1 Route the connector end of the CCU cable to the ECU and make the connection.
You should apply dielectric grease to the pin holes on the cable connector to prevent corrosion, especially if
you are using the autopilot system in saltwater.
2 Route the orange and blue wires from the bare-wire portion of the CCU cable to the location where you plan
to install the alarm
(Installing the Alarm,
If the cable is not long enough, extend the appropriate wires with 28 AWG (0.08 mm
(Tools and Supplies Needed,
(Hydraulic Layouts,
(Installing the Shadow Drive Sensor,
NOTICE
page 16).
(Pump Mounting Considerations,
page 2).
page 9).
page 16).
page 8) and
2
) wire.
15