Replacing the LED board

4.2
Replacing the LED board
The PRIMERGY RX100 S4 server's chassis ID is stored on both the LED board
and the system board. If in the event of failure, the LED board or the system
board which has to be replaced must have the chassis ID rewritten.
Beside the CPU temperature sensor and housing temperature sensor provided
on the system board, an ambient temperature sensor is also included on the
LED board. In case of a defective ambient temperature sensor, please replace
the LED board.
Ê Open the server as described in the
Figure 2: Removing the LED board
Ê Remove the two screws (see arrows).
Ê Unplug the cable.
Ê Pull the LED board in the direction of the housing rear side (approx. 1 centi-
meter).
Ê Take the LED board out of the housing.
Ê Push the new LED board into the front panel. Make sure that the buttons and
LEDs fit in the right positions.