Fujitsu SPARC Enterprise M5000 보충 설명서 - 페이지 25

{카테고리_이름} Fujitsu SPARC Enterprise M5000에 대한 보충 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Fujitsu SPARC Enterprise M5000 36 페이지. Rci build procedure
Fujitsu SPARC Enterprise M5000에 대해서도 마찬가지입니다: 기능 설명서 (30 페이지), 제품 노트 (44 페이지), 시작하기 매뉴얼 (4 페이지)

Fujitsu SPARC Enterprise M5000 보충 설명서
7
On main unit A, execute the setrci -c set command to make the settings of the
host node.
Since main unit A is the first unit, host_no is 1.
XSCF> setrci -c set 1
The command completed successfully
8
On main unit B, execute the setrci -c set command to make the settings of the
host node.
Since main unit B is the second unit, host_no is 2.
XSCF> setrci -c set 2
The command completed successfully
9
On main unit A, execute the setrci -c initconfig command to configure the RCI.
XSCF> setrci -c initconfig
The command completed successfully
10
Execute the setrci -c addconfigcommand on main unit B to expand the RCI
configuration.
XSCF> setrci -c addconfig
The command completed successfully
11
Display the RCI status by executing the setrci -c stat command on main unit A.
XSCF> setrci -c stat
HOST
address 000101ff
Active
LIST
address pwr alm I/F sys-phase ctgry dev-cls sub-cls tm-out
000101ff OFF - ACT --
000102ff OFF - ACT --
003001ff OFF - ACT --
003002ff OFF - ACT --
The command completed successfully
12
Verify that all the RCI device in the RCI connection are incorporated.
C120-E361-04EN
host 0001 0b
-
host 0001 0b
-
disk 0400 04
-
disk 0400 04
-
1.3 RCI Setup
1-7