Fujitsu SPARC Enterprise M5000 제품 노트 - 페이지 23

{카테고리_이름} Fujitsu SPARC Enterprise M5000에 대한 제품 노트을 온라인으로 검색하거나 PDF를 다운로드하세요. Fujitsu SPARC Enterprise M5000 44 페이지. Rci build procedure
Fujitsu SPARC Enterprise M5000에 대해서도 마찬가지입니다: 기능 설명서 (30 페이지), 보충 설명서 (36 페이지), 시작하기 매뉴얼 (4 페이지)

Fujitsu SPARC Enterprise M5000 제품 노트
Updates of the SPARC Enterprise M4000/M5000
Servers Service Manual
The following information supersedes the information in the SPARC Enterprise
M4000/M5000 Servers Service Manual.

Installing the PCI Cassette

Caution – Do not force the PCI cassette into a slot. Doing so can cause damage to the
cassette and server.
1. Align the PCI cassette on the gray plastic guide and install it into the slot.
2. Lock the lever into place to seat the cassette.
Note – As the lever is moved pressure will build up, then just prior to locking into
place the pressure will suddenly release. If the lever locks in place without the
pressure release, the card may not be seated correctly. If this happens the card
should be removed and reinstalled.
Note – When you insert the PCI cassette using hot-swap, the cassette is
automatically powered on and configured. Check that the power LED on the cassette
is LIT to be certain the cassette is correctly seated.
3. Connect all cables to the PCI cassette and reconnect the cable management arm if
necessary.
SPARC Enterprise M4000/M5000 Servers Product Notes
13