Symptom
Documents are not
fed into the ADF
(pickup error occurs
frequently or the
document stops mid-
way).
Paper jams occur fre-
quently.
The scanned images
are elongated.
AP-4
Check this Item
Do the documents qualify the
"Document Quality" and "Double-
feed Detection Condition" in "8
DOCUMENT SPECIFICATON
FOR THE ADF" of the "fi-5650C
Operator's Guide"?
Were the documents fanned before
loaded onto the ADF paper chute?
Are all the consumables (Pick roller
set, Brake roller) installed
correctly?
Is any of consumables (Pick roller
set, Brake roller) dirty?
Is any of consumables (Pick roller
set, Brake roller) worn out?
Is there any debris on the document
feed path?
Do the documents satisfy the
conditions described in "8.2
Document Quality"?
Is there any debris in the ADF?
Are all the consumables (Pick roller
set, Brake roller) installed
correctly?
Is any of consumables (Pick roller
set, Brake roller) dirty?
Is any of consumables (Pick roller
set, Brake roller) worn out?.
Did you cleaned all of the rollers?
Did you adjust the scan scale?
TABLE 1.
Remedy
Use the documents that qualify the "Document
Quality" and "Double-feed Detection Condition"
in "8 DOCUMENT SPECIFICATON FOR THE
ADF" of the "fi-5650C Operator's Guide".
Fan the documents before loading, or reduce the
number of sheets of the documents.
Correctly install the consumable(Pick roller set,
Brake roller), if needed.
Clean the dirty consumables. For details, refer to
4.2 "Cleaning the ADF" of the "fi-5650C
Operator's Guide".
Replace the consumable if needed. For details,
refer to 5 "REPLACING CONSUMABLES" of the
"fi-5650C Operator's Guide".
Remove any debris from the document feed path.
Use documents that satisfy the requirements.
Clean the ADF or remove debris from the ADF.
Correctly install the consumable (Pick roller set,
Brake roller) , if needed.
Clean the dirty consumable.
Replace the consumable if needed. For details,
refer to 5.3 "Replacing the pick roller set" of the
"fi-5650C Operator's Guide".
Clean all the rollers. For details, refer to "4 DAILY
CARE" of the "fi-5650C Operator's Guide"
For Windows 98, Windows Me, Windows 2000
and Windows XP, please select [Scanner and
Camera] in the [Control Panel], then click [Device
Set] tab to adjust the scan scale.
For Windows 95 and Windows NT 4.0, right-click
Scanner Control Center icon in task tray, select
[Option] and adjust the scan scale. Please refer to
"7 Online Setup" of the "fi-5650 Operator's Guide"
and adjust the offset from the Software Operation
Panel (online settings).