Fujitsu ETERNUS DX200 S3 구성 매뉴얼 - 페이지 8

{카테고리_이름} Fujitsu ETERNUS DX200 S3에 대한 구성 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Fujitsu ETERNUS DX200 S3 13 페이지. Hybrid storage systems, all-flash arrays, power synchronized unit
Fujitsu ETERNUS DX200 S3에 대해서도 마찬가지입니다: 수동 서버 연결 구성 (12 페이지), 수동 서버 연결 구성 (12 페이지), 구성 매뉴얼 (28 페이지), 구성 매뉴얼 (18 페이지), 설정 매뉴얼 (15 페이지), 안전 주의사항 (12 페이지)

Fujitsu ETERNUS DX200 S3 구성 매뉴얼
Chapter 2
Setting Up the ETERNUS DX
2.1

Common Settings

This section explains the settings required for all server OSs, regardless of the connection configuration.
See the "ETERNUS Web GUI User's Guide" for details of how to set up and operate ETERNUS Web GUI.
2.1.1

Setting the To-Server Connection Type (Setting the FC Port Parameters)

For each connection configuration, set the indicated items only. All other parameters should be left on their
default values.
Specify "Fabric connection" for connections to the Fibre Channel switches.
Specify "FC-AL connection" for direct connections to the Fibre Channel cards. Specify "Fabric connection" for
direct connections to 16Gbit/s Fibre Channel cards (maximum transfer rate) with a transfer rate of 16Gbit/s.

Table 2.1 FC port parameter settings (FC-AL connection)

Parameter
Connection
Set Loop ID
Loop ID
Transfer Rate
Frame Size
Reset Scope
Release Reservation if Chip is Reset
*1: Set the appropriate value from the following table. Do not use [Auto-negotiation].

Table 2.2 Transfer Rate setting values (for FC-AL connection)

Fibre Channel card maximum speed
16Gbit/s
8Gbit/s
4Gbit/s

Table 2.3 FC port parameter settings (Fabric connection)

Parameter
Connection
Solaris OS
FC-AL
Manual
Values from 0x10 upwards
(Except 0x7D)
See the table below (*1)
2048
I_T_L
Disable
Transfer rate setting value
16Gbit/s CA
8Gbit/s
4Gbit/s
8
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
Copyright 2015 FUJITSU LIMITED
HP-UX, AIX, Windows
ESX, PAN Manager, Citrix XenServer,
Oracle Linux, Oracle VM Server for x86
0x00
8Gbit/s CA
8Gbit/s
8Gbit/s
4Gbit/s
Setting value
Fabric
®
, Linux, VMware
P3AM-7962-08ENZ0