Settings with switches and jumpers

3.7
Settings with switches and jumpers
DIP switch
Figure 9: DIP switch
I
Default setting switch 1 to 4 = Off.
Switch 1 - NVRAM Clear
Switch 1 specifies whether the BIOS default settings are to be loaded or not.
The BIOS default settings are loaded; the user-defined settings are
on
deleted.
The user-defined settings are retained (default setting).
off
Switch 2 - Clear Password
Switch 2 specifies whether the BIOS password should be requested at system
boot if password protection is activated in the BIOS setup (the Password on boot
field is set to enabled in the SECURITY menu).
on
The password prompt is skipped. The user-defined BIOS passwords are
deleted.
The password prompt is active (default setting).
off