Indesit I6T52/AUS 사용 설명서 - 페이지 7
{카테고리_이름} Indesit I6T52/AUS에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Indesit I6T52/AUS 20 페이지.
Adapting the hob
Replacing the nozzles for the hob burners:
1. Remove the hob grids and slide the burners off
their seats.
2. Unscrew the nozzles using a 7 mm socket spanner
(see figure), and replace them with nozzles suited
to the new type of gas (see Technical Specifications
table).
3. Replace all the
components by following the
above instructions in reverse.
Adjusting the hob burners'
minimum setting:
1. Turn the tap to the
minimum position.
2. Remove the knob and adjust the regulatory screw,
which is positioned inside or next to the tap pin, until
the flame is small but steady.
! If the appliance is connected to a liquid gas supply,
the regulatory screw must be fastened as tightly as
possible.
3. While the burner is alight, quickly change the
position of the knob from minimum to maximum and
vice versa several times, checking that the flame is
not extinguished.
! The hob burners do not require primary air
adjustment.
! After adjusting the appliance so it may be used with
a different type of gas, replace the old rating label
with a new one that corresponds to the new type
of gas (these labels are available from Authorised
Technical Assistance Centres).
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet hose in
accordance with current national regulations relating
to "regulators for channelled gas".
Post Installation Checks
Perform post installation checks and ensure proper and
safe operation before leaving. Test all burners individually
and in combination.
Leak Check
Ensure all gas control knobs are in the Off position.
Ensure the gas supply is switched on.
Spray a solution of soapy water onto all gas joints as
well as the full length of any flexible hoses.
UNDER NO CIRCUMSTANCES USE A NAKED FLAME IN
CHECKING FOR LEAKS.
If bubbles appear anywhere, turn the gas supply off, check
all connections and retest. If satisfactory operation cannot
be achieved, contact place of purchase or their appointed
agent for service.
Flame check
Turn each burner on, and ensure that the flame is blue with
minimal yellow tipping. If there is significant yellow tipping,
flame lift off or excessive noise, check pressure and adjust
at the regulator if necessary.
If satisfactory operation cannot be achieved, contact place
of purchase or their appointed agent for service.
Igniter operation
Check that the igniter for each burner successfully ignites
the gas.
If an igniter fails to work, first remove the plug from
the electrical power outlet, and then check that all the
electrical connections are in place.
If satisfactory operation cannot be achieved, contact place
of purchase or their appointed agent for service.
Low flame setting
Check the low flame setting for each hob burner to ensure
that the minimum flame will not be extinguished by air
draughts.
Light the burner.
Turn the control until it engages in the minimum position.
Ensure the flame is stable and will not be extinguished
by air draughts.
To adjust the minimum flame:
Follow the procedure described in the gas conversion
instruction.
DO NOT MODIFY THIS APPLIANCE IN ANY
WAY, OTHER THAN AS DESCRIBED IN THESE
INSTRUCTIONS.
AU
7