HOOD
600
Min.
mm.
Fig. A

Gas connection

This appliance is suitable for use with either a
fl exible connection or rigid copper connection.
Check The Gas Type
WARNING: Before installation, check that the gas
type (natural gas or LPG/Propane) of the cooker is
suitable for the gas type available to the installation. It
is extremely dangerous to use the wrong gas type with
any appliance, as fire or serious injury can result.
This cooker is supplied from the factory already set for
HOT PARTS
It is recommended that an isolating valve and union
be fitted, to enable simple disconnection for servicing.
These are to be in an accessible location.
.
! Make sure the supply pressure conforms with the
values shown in the table entitled "Caracteristics of the
burners and nozzles".
When the cooker is installed between cabinets
(recessed), the gas connection must be effected by
an approved flexible hose with bayonet fitting (BS
669 Current Edition). The gas inlet for the cookers is a
threaded G 1/2 gas female fitting.
Connecting the gas supply
If a flexible hose is used, it should be as short as
Fig. B
Natural Gas. To convert
the cooker to LPG (or
back to Natural Gas
from LPG), follow the
directions later in this
section.
Fit regulator supplied
for Natural Gas (if
applicable) at rear of
appliance, and as close
as practicable to the
appliance.
possible with a maximum length of 1.5 metres;
• The flexible connection must be approved to class B
or D of AS/NZS1869 as a minimum.
• it should not be bent, kinked or compressed;
• it should not be in contact with the rear wall of the
appliance or in any case with parts which may reach
a temperature of 50°C;
• it should not come into contact with pointed parts or
sharp corners;
• it should not be subject to any pulling or twisting
forces;
• it should be easy to inspect along its entire length in
order to be able to check its condition.
• The supply connection point must be accessible
with the appliance installed.
• The inner diameters of the pipe are as follows:
8 mm for LPG;
13 mm for Natural Gas.
Upon completion of installation, check the gas circuit,
the internal connections and the taps for leaks using
a soapy solution (never a flame). Also check that the
connecting pipe cannot come into contact with moving
parts which could damage or crush it. Make sure that
the natural gas pipe is adequate for a sufficient supply
to the appliance when all the burners are lit.
Duplicate Data Plate
Where the data plate is obscured by cabinetry when
the cooker is in the installed position, place a duplicate
data plate on a surface of the cabinetry adjacent to the
cooker.
Electrial connection
Power supply voltage and frequency: 220-240V a.c.
50/60 Hz.
! The supply cable must be positioned so that it never
reaches at any point a temperature 50°C higher than
the room temperature. The cable must be routed away
from the rear vents. Should you require it, you may
use a longer cable, however, you must ensure that the
cable supplied with the appliance is replaced by one
of the same specifications in accordance with current
standards and legislation.
Your appliance is supplied with a 13 amp fused
plug that can be plugged into a 13 amp socket for
immediate use. Before using the appliance please read
the instructions below.
WARNING - THIS APPLIANCE MUST BE EARTHED.
THE FOLLOWING OPERATIONS SHOULD BE
CARRIED OUT BY A QUALIFIED ELECTRICIAN.