acaia Pearl 사용자 설명서
Default Weighing Unit Setting [ Unit ]
1. The Default Weighing Unit is set to grams if [ 9 ] is selected and ounce if [ o2 ] is selected.
2. Tap the tare button to switch the Default Weighing Unit between gram and ounce.
Weighing Resolution Setting [ rESoL ]
1. The default Weighing Resolution is set to [ dEFAUt ]; the division is 0.1 g for weights of 1000
g or less and 0.5 g for weights between 1000 g and 2000 g.
2. When the Weighing Resolution is set to high, the division will be 0.1 g throughout the entire
time from 0 g to 2000 g.
3. Tap the tare button to switch the weighing resolution between [ dEFAUL ] and [ hiGh ].
Espresso Mode Setting [ NoDE_1 ]
1. The default Espresso Mode Setting is set to OFF, which means this mode is disabled.
2. ON: The Espresso Mode is enabled.
3. OFF: The Espresso Mode is disabled.
Dual Display Mode Setting [ NodE_2 ]
1. By default, the Dual Display Mode Setting is set to ON, which means this mode is enabled.
2. ON: The Dual Display Mode is enabled.
3. OFF: The Dual Display Mode is disabled.
Timer Starts with Flow Mode Setting [ NodE_3 ]
1. By default, the Timer Starts with Flow Mode Setting is set to OFF, which means this mode is
disabled.
2. ON: The Timer Starts with Flow Mode is enabled.
3. OFF: The Timer Starts with Flow Mode is disabled.
Beverage Mode Setting [ NodE_4 ]
1. The default Beverage Mode is set to OFF, which means this mode is disabled.
2. ON: The Beverage Mode is enabled.
3. OFF: The Beverage Mode is disabled.
Auto-Tare Mode Setting [ NodE_5 ]
1. The default Auto-Tare Mode is set to ON, which means this mode is enabled.
2. ON: The Auto-Tare Mode is enabled.
3. OFF: The Auto-Tare Mode is disabled.
Reset to Default Setting [ rESEt.d ]
1. Select "YES" to reset all settings to default value.
Bluetooth Setup Setting [ bt_SEt ]
1. ON: The Bluetooth is enabled. The scale allows Bluetooth connection. Users may connect
the scale with Acaia apps.
2. OFF: The Bluetooth is disabled. The scale does not allow any Bluetooth connection.
11