Shaker type dust collector
Problem
Pressure differential
is too high
Air leaks in the system
Air volume through
the collector is less
Air leaks in the
than original design
collector
Air is minimal or
not sufficient
Temperature is higher
than normal in
collector.
Dust filtered is not
compatible with filter
enveloppe
Presence of humidity
Rapid deterioration
in filtered air
of filter envelope
Incorrect installation
of filter envelope
Abrasion of filter
envelope due to
high inlet velocity
Probable cause
Refer to section above on Pressure differential.
Check doors, ducting and seal leaks.
Examine dust storage section, access doors,
explosion vents and inlets to and from collector.
Seal all leaks.
Check filter envelope (any debris, clogged filter,
obstruction in airflow). Remove or clean.
Check and evaluate filtered air temperature.
Do not exceed such temperatures.
Check for dust properties to be filtered. A.Q.C.
representative or consultant will guide you for
compatible filter. Replace if necessary.
Reduce or modify humidity factor.
Replace filter envelope.
Examine the filter envelope and locate damages
caused by a faulty installation Repair or replace
filter enveloppe if necessary.
Examine the filter envelope for holes or punctures.
If so, install a diffuser at air inlet.