Aqua Computer AQUASTREAM XT USB 사용자 및 설치 설명서 - 페이지 16

{카테고리_이름} Aqua Computer AQUASTREAM XT USB에 대한 사용자 및 설치 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Aqua Computer AQUASTREAM XT USB 20 페이지.
Aqua Computer AQUASTREAM XT USB에 대해서도 마찬가지입니다: 사용자 및 운영 매뉴얼 (16 페이지)

Aqua Computer AQUASTREAM XT USB 사용자 및 설치 설명서
aqua
computer
AQUASTREAM XT
By clicking the button "Reset maximum pump speed", the currently determined
maximum pump speed will be reset and the pump will repeat the start-up process.
The button is effective for both manual and automatic mode.
The parameter "Minimum pump speed" determines the minimum speed for both
automatic and manual mode. If this speed is not attained during start-up, the max-
imum speed detection will be repeated until the minimum speed setting is attained.
If this parameter is set too high, the pump will repeat the start-up process over and
over again – therefore set to a speed at which the pump runs stable.
The parameter "Maximum pump speed" limits the maximum speed in automatic
mode – the pump will not operate faster than this speed even if a higher speed
setting would be possible.

13. Fan configuration (aquasuite)

13. Fan configuration (aquasuite)
13. Fan configuration (aquasuite)
13. Fan configuration (aquasuite)
Select "Fan" from the device list for the device to be configured.

13.1. Fan mode

13.1. Fan mode
13.1. Fan mode
13.1. Fan mode
In the upper area, current fan data (speed, power output, voltage) is displayed as
plain text as well as in a diagram.
Select the desired mode of operation for the fan output below the diagram. If
"Manual fan settings" is selected, the fan output can be set to a fixed value. In
"Automatic temperature control" mode, the fan power will be dynamically adjusted
depending on either the current water temperature sensor reading or an external
temperature sensor.

13.2. Manual fan settings

13.2. Manual fan settings
13.2. Manual fan settings
13.2. Manual fan settings
When using manual mode, set the desired output power here.

13.3. Automatic temperature control

13.3. Automatic temperature control
13.3. Automatic temperature control
13.3. Automatic temperature control
When using the automatic temperature control mode, select the sensor to be eval-
uated and set the desired target temperature. The controller speed setting should
not be changed in normal setups.

13.4. Fan settings

13.4. Fan settings
13.4. Fan settings
13.4. Fan settings
When using the automatic temperature control mode, the output range can be
limited in both directions ("Minimum power"/"Maximum power"). The check box
"Hold minimum power" determines whether the fan will be switched off for low
temperature sensor readings (box not checked) or remain active at the set minim-
um speed (box checked). Set minimum power to a value at which the connected
fan reliably starts up.
- 16 -
Aqua Computer GmbH & Co. KG
© 2007-2013
Gelliehäuser Str. 1, 37130 Gleichen