8.9. Window „XML & logdata"
The aquasuite offers extensive protocol and evaluation functions. To use
these, the log function must be switched on. Also set the interval in which the
data shall be saved in the database of the aquasuite.
In the menu "extra" you are able to analyze the log data. Select the pump
from the device list and click on the button "load data". Then drag the desired
values from the right list to the left into the diagram and select a colour.
To be able to use the values from the aquasuite software in other
programmes, these can be stored into a XML file. Activate the option "start
automatic data export" and set a refresh interval as well as an output file.
8.10. Window „Diagrams"
The chart window represents the most important values like temperatures,
pump-, regulator- and fan data graphically. The desired values can be
selected below. Time periods can be marked and extended or reduced by
mouse wheel within the diagram.
9. Trouble shooting
9.1. Reset of the pump values
There are two ways to put the pump into its delivery state. This makes sense if
the pump no longer works correctly or you have set nonsensical values in the
aquasuite and have stored them into the pump.
You can reset the pump by software via the aquasuite software by selecting
the menu item "set factory defaults" in the aquasuite software from the menu
"aquastream XT".
The pump can alternatively be reset also directly by a jumper, what at serious
problems is recommendable. To do that turn off the computer and put the
enclosed jumper on the connection "deaeration / ext. temp". Switch on the
computer again and remove the jumper.
9.2. Spare parts
Item numbers of the original spare parts and accessories for the aquastream
XT pump :
Description
Connection cable for aquabus/tacho
ATX-short-circuit-plug