SET-UP GUIDES CONT.
BOTTLE FILLER ELECTRONICS:
Please review the installation section first. Before installing upper panel assembly with electronic
bottle filler: change units from gallons (default setting) to litres. To ease access to the remote
toggle button for programming once the panel assembly and fountain is installed, feed the
remote toggle button through the fountain mounting plate.
Factory default program settings:
• Units: Gallons
• Unfiltered unit
• Flow meter = Rate selected
• Filter capacity = 1250 gallons (4731L) for VersaFilter
• Bottle count = 0.5L (1 bottle)
• Flow rate = 1.2 GPM
• 20s max dispense time.
To change the program settings, follow these steps:
DISPLAY
ACTION
000000000 BOTTLES
Depress button for 3 seconds to enter into the following menu settings and make changes.
REUSED
Note: at anytime it will exit menu and save settings when idle for 10 seconds (no button press) and
(Home Screen)
revert back to Home Screen.
LTR/GAL
Depress button for 3 seconds to change from Gallons to Litres, or momentary press to advance to
GAL
next menu.
UNFILT/FILT?
Depress button for 3 seconds to change from Unfiltered to Filtered unit, or momentary press to
UNFILT UNIT
advance to next menu
FLOW METER?
Depress button for 3 seconds to change from Rate Selected to (Flow) Meter Enabled, or
RATE SELECTED
momentary press to advance to next menu
SELECT RATE
To change flow rate, momentarily depress button to change whole gallon digit.
1.2 GPM UNIT
Hold button 3 seconds to advance to TENTHS of gallon digit.
Depress momentarily to change the digit.
Hold button 3 seconds to advance to the next menu.
RESET 000000000
Depress button for 3 seconds to reset Gallon or Litre count, or momentary press to advance to
GALLON CNT
next menu
[LTR COUNT]
FILT CAPAC
Depress button for 3 seconds to change filter capacity to 3000 GAL [11355 Litres] for Versafiller I
OF 1250 GAL
or Galaxi green filter, or momentary press to advance to next menu
[4731 LTR]
3 sec rule?
Depress button for 3 seconds to switch from 0.5L bottle to 3 sec rule, or momentary press to
0.5L
advance to next menu. (The 3 Sec rule increases the bottle count based on a 3 second dispense.)
RESET 00000000
Depress button for 3 seconds to reset (Home Screen) BOTTLES REUSED count, or momentary
BOT COUNT?
press to advance to next menu.
Bot Filler
Depress button for 3 seconds to change maximum dispense time to 10, 20, or 30 seconds, or
Set_time:20s
momentary press advance to next menu.
RUN CAL
Depress button for 3 seconds to run calibration again, or momentary press to advance to next
AGAIN?
menu.

REMOVING FROM SERVICE

• Disconnect the power supply.
• Disconnect the water supply.
• Drain cooler by removing grille, closing supply valve, and draining water.
• Remove the drain plug and bubbler.
Your Partner in Cool.
12

MAINTENANCE

The only maintenance required is the removal of dirt and lint from the condenser. Inspection
should be made at 3 mount intervals. Remove the grille and clean the condenser with a vacuum
attachment.
This unit is equipped with a hermetically sealed compressor. No additional lubrication is
required. The fan motor installed on this unit seldom needs oiling. If required, a few drops of
SAE 10 oil should be used.
Aqua Cooler recommends the unit to be checked every month, ensuring there is no blockage in
the condenser or in the back of the unit. Please remove all potentially harmful factors to prevent
any scratch or damage to the unit.
If customers require the unit's spare parts information, please contact the Aqua Cooler service
department for further assistance. The direct line is located on the back of this manual.

TROUBLESHOOTING

PROBLEM
POSSIBLE CAUSE
Controller is faulty
Temperature sensor is faulty
Controller display is faulty
No water flowing out of
Water source has been suspended
the unit
The system is clogged
Solenoid valve is faulty
Unit does not dispense cold
The cooling controller is turned off
water
Power failure
The ventilation around the unit is
insufficient
System malfunction
The temperature of the incoming water
it too high
Unit is noisy during operation
Chiller unit in the machine is not level
Chiller unit is touching other objects
The water being dispensed
This is not uncommon with new
has a strange taste.
water oolers. Do not worry, this is not
dangerous to your health.
MARKS
The appliance complies with applicable ACMA regulatory arrangements (Regulatory Compliance
Mark) and WaterMark WMTS 105:2016.
REMEDY
Check sensor connections.
Contact Aqua Cooler service team.
Restore water supply
Check the pipes
Check controller and cable connections
Check the position of the mechanical thermostat
and set to desired temperature
Check the power cord is properly plugged in or if
there is a power outage
Ensure sufficient ventilation space around the unit
Contact Aqua Cooler service team.
Ensure the unit is not placed in direct sunlight or
close to other heat sources
Place the chiller unit on a level flat surface.
Ensure the chiller is standing free of any surrounding
objects.
Flush as per installation instructions. Perform
cleaning procedure.
13