Electrical Installation
The procedure for connecting the inset light fixture to the corresponding electrical
connections is as follows:
•
Feed input and output cables through corresponding side mounted gland on inset
base
•
Connect each conductor of input cable to separate joint connector (not supplied). One
for +24VDC, one for GND (0VDC) and one for Dim (0-10V) control line.
•
Connect each conductor of output cable to corresponding joint connector
•
Connect each conductor of light fly lead to corresponding joint connector as per table
•
Tighten each cable gland to ensure sealing
Note: Do not cut or modify the fly lead attached to the AV-HLI2 light fixture
Mechanical Installation
5" Configuration:
The procedure for installing an inset light fixture to a 5" base is as follows:
•
Ensure the M5 screw holes and flange area on the 5" inset base are clean
•
Lower the light fixture onto the inset base, ensuring all electrical connections are
properly terminated and fly lead is free and clear of the mounting surface
•
Align the screw holes of the inset light fixture with those of the inset base and fasten
using silicone greased M10x15 counter sunk screws
•
Tighten screws to 4.9 Nm
8" Configuration:
The procedure for installing the adaptor ring onto the inset light fixture and fitting to a 8"
base is as follows:
•
Ensure the M10 screw holes and flange area on the 8" inset base are clean Insert the
provided O-ring into the O-ring groove of the adaptor ring
•
Lower the light fixture onto the inset base, ensuring all electrical connections are
properly terminated and fly lead is free and clear of the mounting surface
•
Align the screw holes of the inset light fixture with those of the inset base and fasten
using silicone greased M5x12 counter sunk screws
•
Tighten screws to 4.9 Nm
12