Avlite AV-HLI2 Руководство по установке и обслуживанию - Страница 12

Просмотреть онлайн или скачать pdf Руководство по установке и обслуживанию для Осветительное оборудование Avlite AV-HLI2. Avlite AV-HLI2 16 страниц. Inset heliport light
Также для Avlite AV-HLI2: Руководство по установке и обслуживанию (12 страниц)

Avlite AV-HLI2 Руководство по установке и обслуживанию
Electrical Installation
The procedure for connecting the inset light fixture to the corresponding electrical
connections is as follows:
Feed input and output cables through corresponding side mounted gland on inset
base
Connect each conductor of input cable to separate joint connector (not supplied). One
for +24VDC, one for GND (0VDC) and one for Dim (0-10V) control line.
Connect each conductor of output cable to corresponding joint connector
Connect each conductor of light fly lead to corresponding joint connector as per table
Tighten each cable gland to ensure sealing
Note: Do not cut or modify the fly lead attached to the AV-HLI2 light fixture
Mechanical Installation
5" Configuration:
The procedure for installing an inset light fixture to a 5" base is as follows:
Ensure the M5 screw holes and flange area on the 5" inset base are clean
Lower the light fixture onto the inset base, ensuring all electrical connections are
properly terminated and fly lead is free and clear of the mounting surface
Align the screw holes of the inset light fixture with those of the inset base and fasten
using silicone greased M10x15 counter sunk screws
Tighten screws to 4.9 Nm
8" Configuration:
The procedure for installing the adaptor ring onto the inset light fixture and fitting to a 8"
base is as follows:
Ensure the M10 screw holes and flange area on the 8" inset base are clean Insert the
provided O-ring into the O-ring groove of the adaptor ring
Lower the light fixture onto the inset base, ensuring all electrical connections are
properly terminated and fly lead is free and clear of the mounting surface
Align the screw holes of the inset light fixture with those of the inset base and fasten
using silicone greased M5x12 counter sunk screws
Tighten screws to 4.9 Nm
12