A.H. Systems PAM-0118 운영 매뉴얼 - 페이지 6

{카테고리_이름} A.H. Systems PAM-0118에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. A.H. Systems PAM-0118 13 페이지.

A.H. Systems PAM-0118 운영 매뉴얼
A.H. Systems Model PAM-0118 Pre-Amplifier

OPERATING INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

The Model PAM-0118 preamplifier is shipped completely assembled. Simply supply the
required 15 Vdc to the preamplifier.

MOUNTING INSTRUCTIONS

The Model PAM-0118 is a bench top preamplifier. Ordinarily, the preamplifier should be
used near the test equipment, rather than at the antenna. There are a few exceptions,
however, including:
OPERATING INSTRUCTIONS
Operation of the Model PAM-0118 preamplifier is quite simple. The unit is turned on by
first plugging the phone-type plug from an external power supply into the power input
connector. The power supply is then plugged into the appropriate line voltage supply.
Ensure that the preamplifier has sufficient time (15 minutes) to warm up and stabilize.
Pushing the switch to the on position turns on the preamplifier and the power indicator
LED will light. The output signal is taken from the jack marked "OUTPUT" and fed to the
desired amplifier or test equipment. The input signal is connected to the jack marked
"INPUT".
The Model PAM-0118 preamplifier is not critical in regards to source and load VSWR
and will remain unconditionally stable with any magnitude and phase of source and
load VSWR. However, input signals greater than -30 dBm are not recommended, as
they will saturate the preamplifier and amplitudes higher than +10 dBm will damage
the preamplifier.
© A.H. Systems inc. – April 2009
REV B
• Magnetic Loop antennas in quiet locations. These antennas have relatively low
sensitivity or gain. When used in quiet locations, they do not provide much
background noise to the system.
• Long cable runs. If the cable loss is high, performance will improve with the
preamplifier mounted near the antenna.
CAUTION:
6