Most common causes of failure:
• Excessive power applied to the RF input (such as ESD to the input
• Improper connection sequence (sequence such as application of signals to
• Excessive DC voltage applied
• Storage near strong EMI or RFI fields
• Loose connections causing intermittent events
An over voltage at the preamp input will damage the preamplifier. This type of
damage is without fault of A.H. Systems and will void the warranty.
To connect:
1. Apply DC Voltage
2. Connect output load
3. Apply RF input
To disconnect:
1. Remove RF input
2. Remove load
3. Remove DC voltage

RANGE OF ENVIRONMENTAL CONDITIONS

This equipment is designed to be safe under the following environmental
conditions:
While the equipment will not cause hazardous conditions over this
environmental range, performance may vary.
© A.H. Systems inc. – April 2009
REV B
connector or antenna connected to the input connector)
the preamplifier before powering up)
Indoor use
Altitude: up to 2 km
Temperature: 5° C to 40° C
Maximum relative humidity: 80% for temperatures up to 31° C.
Decreasing linearly to 50% at 40° C
Pollution degree 2: Normally non-conductive with occasional
condensation.
DC supply voltage fluctuations not to exceed +/- 10% of the nominal
voltage.