Coin Washer Default Cycle (Preset at Factory)
The following table shows the complete details for the coin washer default cycle.
Bath
Bath Cycle Time (min.)
Prewash
0
Wash
9
Rinse 1
4
Rinse 2
0
Final Rinse
5
*NOTE:
These default values are preset and cannot be changed.
Rapid Advance Mode
To enter the Rapid Advance mode, push and hold the Cold water temperature button and then push the
programming button on the controller. There will be no observed change to the washer or the display. The
Rapid Advance mode can be entered from either the Idle mode or during the cycle. To rapid advance to
the next step in the wash cycle, push both Start and Warm temperature buttons at the same time. The
display will show an "Ad" (advance) in the display. The washer will advance to the next bath segment. The
water will drain before the advance will occur.
To exit the Rapid Advance mode, push and hold the Cold temperature button for 5 seconds or more.
NOTES:
Step 1: When the Rapid Advance mode is used, the cycle time will no longer be correct.
Step 2: By skipping steps with rapid advance, the door may not open immediately at the end of the
cycle.
Main Control Printed Circuit Board
This control has a battery that allows memory retention in case of main power loss. The battery may need
replacing if time of day options are not functioning properly.
Remove power from machine and lockout safely.
Remove battery from socket on circuit board and reinstall new battery (#8612-001-001).
CAUTION:
nal clock and not allow re-startup of internal clock, possibly causing programming trouble.
6
Part # 8533-073-001 11/11
Water Temp.
CH
CC
CC
Do not soft reset this machine when installing new battery. This will reset inter-
Water Level*
Delay Fill
LO
t
LO
t
LO
t
Spin Time (min.)
IS *
0
0
0
4
0