COZY BFT102 and 설치 및 작동 지침 매뉴얼 - 페이지 14

{카테고리_이름} COZY BFT102 and에 대한 설치 및 작동 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. COZY BFT102 and 18 페이지. Blue flame vent free heaters
COZY BFT102 and에 대해서도 마찬가지입니다: 설치 및 작동 지침 매뉴얼 (19 페이지), 설치 및 작동 지침 매뉴얼 (19 페이지)

INSTALLING THE VFB BLOWER (BFT201 / BFT202, BFT301 / BFT302 MODELS ONLY)
STEP 1. Remove blower assembly from shipping carton.
STEP 2. Insert blower assembly into upper back of heater (See Figure 11).
STEP 3. Secure blower to heater using three #8 screws (provided) through holes pre-punched in heater back.
STEP 4. Locate mounting holes for switchbox (See Figure 11).
STEP 5. Secure switchbox to heater using two #8 screws (provided).
STEP 6. Plug power cord into 115 volt three-prong grounded receptacle.
CAUTION:
Always unplug power cord before servicing or cleaning heater. This appliance is equipped with a three-
prong (grounding) plug for your rotection against shock hazard and should be plugged directly into a
properly grounded three prong receptacle.
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after servicing.
FIGURE 11

BLOWER INSTRUCTIONS

Blower Motor
If any of the original wire supplied with
the appliance must be replaced, it must
be replaced with a wire of at least a
105
C temperature rating.
º
WIRING DIAGRAM / VFB BLOWER
Page 14
Switchbox
Blower Assembly
Fan
Switch
Power
Cord