DeZurik KGC-MC 사용 설명서 - 페이지 12

{카테고리_이름} DeZurik KGC-MC에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. DeZurik KGC-MC 17 페이지. Metal cutting knife gate valves

DeZurik KGC-MC 사용 설명서
DeZURIK
KGC-MC METAL CUTTING KNIFE GATE VALVES
Seat Replacement

Reassembling the Valve

1. 1.Reassemble the pipeline flange and
flange bolts, or reassemble the valve in the
pipeline if the valve was removed. Refer to
the requirements in the "Installation"
section.
2. If the actuator is a powered actuator,
reconnect power to the actuator.
3. Pressurize the pipeline and inspect the
valve for leaks.

Replacing the Gate

Note: If the gate is for a KGC-MC metal cutting
valve with a pneumatic cylinder actuator, the
clip and gate are match drilled to handle high
frequency cycling. In this case, refer to the
Replacing the Clip section and drill out the
gate holes that align with the clip.
See Figure 6 for component identification.
WARNING!
Pipeline pressure can cause personal injury or equipment damage. Relieve
pipeline pressure before removing gate stem and packing gland nuts.
1. Relieve the pressure in the pipeline and close the valve.
WARNING!
Accidental operation of power actuator can cause personal injury or equipment
damage. Disconnect and lock out power to actuator before servicing.
2. Disconnect and lock out power to prevent accidental operation of the actuator.
3. Remove the pipeline flange bolts, and remove the valve from the pipeline.
4. Remove the actuator, actuator yoke, packing gland (A4), scraper rings (A2) and packing (A8) from
the valve.
5. Remove and inspect the gate (A3). If the gate appears to be scratched or galled due to too-long
flange bolts in the chest area of the body, check for body damage in the tapped flange holes within
the chest cavity. Carefully check the seat and guides for damage. Repair or replace the body, as
appropriate.
D11060
continued
Page 12
Figure 6
November 2020