Installation

The type of materials carried in the pipeline and the location of the valve determine the correct
installation procedure.
Liquids and Gases
1. Before installation, remove foreign material such as weld spatter, oil, grease, and dirt from the
valve and pipeline.
2. Install the valve as shown in Figure 2.
3. Ensure the valve and flanges are concentric to ensure proper flange sealing.
4. Tighten the flange bolts or studs in a crisscross pattern.