DeZurik PEC 4200 매뉴얼 - 페이지 8
{카테고리_이름} DeZurik PEC 4200에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DeZurik PEC 4200 18 페이지. Eccentric valves
DeZURIK
3650-7200 PEC Eccentric Valves
Installation (continued)
Suspended Solids
If the pipeline carries suspended solids such as paper stock of 2 percent or higher consistency, mining
slurry, or raw sewage:
1. Before installation, remove foreign material such as weld spatter, oil, grease, and dirt from the
valve and pipeline.
2. Install the valve as shown in Figure 3.
a. In H
ORIZONTAL
upward as the valve opens.
b. For V
ERTICAL
NOTE: In the case of limited space where both the
recommended seat orientation shown and the
recommended plug orientation described in 2a above, are
not possible, the recommended plug position shall
always take precedence.
For Pump Isolation Service, install the discharge valve
with the seat toward the pump and with the plug rotating to
the top of the pipeline in the open position. On the suction
side, install the valve with the seat toward the pump.
3. Tighten the flange bolts or studs in a crisscross pattern.
4. Ensure the valve and flanges are concentric to ensure proper flange sealing.
D10019
pipelines, install the valve so that the plug is horizontal and rotates
pipelines, install the valve with the end marked "S
Figure 3 — Liquids with Suspended Solids
Page 8
" at top of valve.
EAT
April 2015