Avocent ACS 6000 릴리스 정보 - 페이지 2
{카테고리_이름} Avocent ACS 6000에 대한 릴리스 정보을 온라인으로 검색하거나 PDF를 다운로드하세요. Avocent ACS 6000 5 페이지. Advanced console server
Avocent ACS 6000에 대해서도 마찬가지입니다: 릴리스 정보 (4 페이지), 빠른 설치 매뉴얼 (20 페이지), 릴리스 정보 (5 페이지)
1. Web User Interface usability enhancements:
New buttons for Power Control in Access page when at least one Avocent Power
Management Distribution Unit (PM PDU) is connected to the appliance (serial/aux port
with Power Profile).
The PDU table under Power Management node:
o Status column shows the actual status of the PDU: On Line, Unlicensed or Not
Available.
o Outlets column shows the number of outlets with ON status and the total number
of outlets.
o Upgrade Firmware button allows to select more than one PDU to perform
firmware upgrade (the multiple selections are supported only for the PDU in
this version).
Overview node under PDU drill-down has summary of PDU data monitoring.
2. Usability Enhancements for CLI:
Consolidate power control operations: on, off and cycle to manage PDU (all possible
outlets), individual outlets, and range of outlets, merged outlets to the serial port.
3. Pool of CAS serial ports feature is now available in the ACS 6000 console server. An
administrator can create a pool of serial ports where each serial port in the pool shares a pool
name, TCP Port Alias, IPv4 Alias and IPv6 Alias. The first available port in the pool is used as
the serial port for connection.
4. New Protocol Raw mode is available for CAS profile. Authorized users can make a Raw Socket
connection to the console of a connected device.
5. Support the PDU with firmware version 2.0.0, and allow firmware upgrade of the PDU thru
serial port.
6. The authorization group via RADIUS authentication is accepting new syntax and more than one
attribute FRAMED-FILTER-ID in one single message.
New Syntax:
Framed-Filter-Id = "[group_name=] <group1> [, <group2>][;]"
Framed-Filter-Id += "[group_name=] <group11> [, <group22>][;]"
Examples:
1) Framed-Filter-Id = "group1, my_group, group4
Framed-Filter-Id += "group11, group4"
2) Frame-Filter-Id = "group_name=group1,my_group,group4;
7. Apache upgrade from version 2.2.9 to version 2.2.14 + patches (cve-2009-3555.patch and cve-
2009-3555-enhancement.patch) because of the following security issues: CVE-2009-3555,
CVE-2009-2699, CVE-2009-3095, CVE-2009-3094, CVE-2009-2412, CVE-2009-1891, CVE-
2009-1195, CVE-2009-1890, CVE-2009-1191, CVE-2009-0023, CVE-2009-1955, CVE-2009-
1956, CVE-2008-2939.
8. Event Notifications: new events for Environmental External Sensors connected in PDU: