Aqua Lung CORE 서비스 매뉴얼 - 페이지 16

{카테고리_이름} Aqua Lung CORE에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aqua Lung CORE 18 페이지.

Aqua Lung CORE 서비스 매뉴얼
Cleaning brass and stainless steel parts.
1.
Pre-clean by soaking in NETALU diluted to 25%.
2.
Cleaning in an ultra-sonic bath filled with a mixture of washing-up liquid + hot water. If some resistant deposits remain then
fill the ultrasonic bath with diluted white vinegar and repeat. DO NOT put plastic, rubber, silicone or anodised aluminium
parts in contact with vinegar.
3.
Rinse in demineralised or fresh water to avoid calcium deposits. Soak for 10 minutes. Dry with filtered low pressure air and
then check that their condition is now suitable for re-use.
Cleaning plastic, rubber and anodised aluminium parts.
For anodised aluminium parts: soak in a « NETALU diluted to 25% ». Rinse in fresh water and dry with low-pressure filtered air.
For plastic parts. (casings, plugs...): clean in an ultrasonic bath containing a mixture of washing-up liquid and hot water. Use only a
ATTENTION: Do not place plastic and rubber parts in contact with acid solutions. This could alter their physical
properties and cause degradation and premature breakdown.
Disinfecting parts
For disinfection, leave plastic and metal parts to soak for 20 minutes in a bath of STERANIOS 2% ref. 382062 (ready to use). Rinse
the parts thoroughly after soaking. Toxic product, follow the instruction for its use.
Cleaning parts for Nitrox/O2 use.
1.
Metal parts: Pre-clean by soaking in NETALU diluted to 25%.
2.
Ultrasonic cleaning in Promoclean TP108 diluted at 5%.
3.
Rinse in demineralised water. Soak for 10 min.
4.
Dry in the open air in a clean and dust-free atmosphere. Place the parts on a white cloth, allow to dry and check after drying
that the cloth shows no grease deposits and that the condition of the parts is appropriate for re-use with Nitrox/O2.
Cleaning hoses.
Refer to support "Hose inspection and cleaning procedure".
Wiping.
To wipe parts, use a white filter paper, a pure cotton cloth or any other material that
Inspection.
Visually check under a white light (day light or artificial light).
The parts are completely free of any traces of:
organic materials (oil, grease, paint, rust...)
1.
2.
cleaning agents
3.
dust
4.
humidity
Lubrication.
When handling O-rings wear unpowdered latex gloves. It is important not to allow contact between the internal components and the
skin or any other source of contamination when the regulator is being prepared for Nitrox use. All seals should be lubricated with
Christolube MCG111. Cover the seals with a light film of grease and remove any excess by rolling the seal between finger and thumb.
Do not use an excess of grease; this can have the effect of accumulating particles that could damage the O-rings.
nd
Service Manual Core 2
Rev. 05/2015
Procedure A – Cleaning and Lubricating
(All Aqua Lung regulators)
toothbrush with nylon bristles to remove any deposits. Rinse in fresh water and dry with low-
pressure filtered air.
stage
Service Manual Core 2
does not produce
fluff.
nd
stage
16