Avonic CM-CON100 사용자 설명서 - 페이지 9

{카테고리_이름} Avonic CM-CON100에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Avonic CM-CON100 16 페이지. Ptz camera controller
Avonic CM-CON100에 대해서도 마찬가지입니다: 사용자 설명서 (12 페이지), 사용자 설명서 (10 페이지), 사용자 설명서 (13 페이지), 사용자 설명서 (11 페이지)

Avonic CM-CON100 사용자 설명서

RS485 network connection diagram

To connect multiple cameras by RS485, the cameras are attached to a 2-wire twisted pair bus (max length
1200m) that is terminated at both ends with a 120 Ω impedance resistor. The maximum distance from the bus
to the camera or controller is 5m.

Addressing Multiple Cameras

In case more cameras are connected to the controller, each camera needs to be addressed the right way to a
camera number of the controller.
The following settings need to match in both camera and controller:
1.
Protocol (VISCA, PELCO-p or PELCO-d)
2.
Camera address number (1, 2 or n)
3.
Communication settings as baud rate (9600), parity, etc.
See page 12 (Camera Settings) for more information. The following section of this manual describes how to set
up the controller.
www.avonic.com
Back to top
9