CPS AR2700A 운영 매뉴얼 - 페이지 9

{카테고리_이름} CPS AR2700A에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. CPS AR2700A 17 페이지. Refrigerant recovery / recycling system

1.
Open the manifold valve (HI an/or LO) to choose the charge path into the car A/C
system.
2. Open the oil injection valve. Note: the oil level in the oil
injection bottle.
3. Once the required amount of oil has been injected, close
injection valve.
4. Proceed immediately to Charge Function.
Charge Function:
A/C system should be in a deep vacuum.
1. Connect HI and LO side service hoses to A/C system.
Open the service hose valves.
2. Open the manifold valve (HI an/or LO) to choose the charge path into the car A/C
system.
3. Push the SET/RESET key on scale keypad until the LCD displays "READY"
and charge amount.
4. Push LB/KG Key on scale keypad to select LBS or KGS units of measure.
5. Use the UP or DOWN arrow keys to set the charge weight. Note: If the unit
alarms, the remaining refrigerant capacity has been reached.
6. Push the GO/HOLD key. The unit will begin to automatically charge the
A/C system.
7. The LCD will show refrigerant being dispensed.
8. Once amount shown on LCD meets the programmed amount, the charging will
automatically stop and the unit will beep. Go to Step 9.
If the programmed charge weight is not reached (The unit will alarm if there is no
refrigerant flow for more than 3 minutes) on LCD follow steps A-D:
A. Close (I) the HI manifold valve.
B. Start A/C System.
C. Open (O) LO manifold valve.
D. Once programmed charge amount is reached, the charging will automatically
stop and the unit will beep.
The following is hose purge sequence to ensure no residual liquid
refrigerant is left in the service hoses:
9. Remove the HI side service hose from the A/C system.
10. Start A/C System.
11. Open (O) both LO and HI manifold valves. Once LO and HI manifold gauges are
reading the same pressure, hose purge is complete.
12. Disconnect LO side service hose from A/C System.
Before running the charge function, the
9
OPERATION
Oil Injection Port